Reconnect the wire harness if it’s loose. Stored error codes can be retrieved in by putting the appliance in service mode or pressing and holding a sequence of buttons on the user display. Skip through the fault codes and find the corresponding one: you will find out what might have caused the problem, and how to solve it. The 14e error code on that model is a ice maker sensor error, the sensor is located on the control head of the ice maker, you will need to replace it, the part is listed below: Ice maker control assembly - click here for part. Refer to next. In the defrost mode, the valve opens and lets hot gas into the evaporator. When the CV compartment defrosting heater operates, the LED is turned on. This unit is installed in the liquid cooling loop to prevent the compressor from overheating. Others will store the error code in the error memory. You can hear water bubbling in the refrigerator. A clogged filter drier’s surface is covered with snow. Freezer evaporator defrost system failure, Refrigerator evaporator defrost system failure, Unplug the refrigerator and remove the electronic control board cover. The difference is that it features a water reducer. Check the Comp and Cycle. ), Check the input voltage. Actually, If there is not a problem, it is desirable to replace Main and Panel PCB With the oscilloscope after a cable problem confirming. • This is normal. Check if the DC 15V output is less than 13.5V. Please, always clean the removable coarse filter on the ¾ side. 2-The first time the error occurs after the update, touch OK. This is much more cost effective and has a far less impact on the environment than a complete appliance replacement. "e" at the lowest order digit of the R compartment. Check if the sensor is open or shorted The voltage between the Main PCB CN30 pins 1 and 6 should be within the 4.5V~1.0V range. The voltage of the MAIN PCB CN74 1↔4: should be between 7V~12V. Check if the door has been open for a long time or if hot food has been stored in the compartment. Reconnect the wire harness if it’s loose. Diagnostics: Low pressure in the suction line is a clear sign of a clog in the capillary tube. "b" at the second lowest order digit of the F compartment. After changing the Ice Maker(R), plug the refrigerator power code again, and check the operation. Unplug the refrigerator and check the wire harness connection on the refrigerator compartment temperature sensor. This website uses cookies to ensure you get the best experience Our, Brother Sewing and Embroidery Machine Error Codes, Shark IQ Robot Vacuum Cleaner Error Codes, Electrolux Robot Vacuum Cleaner Error Codes, Anker Eufy Robovac Robot Vacuum Error Codes, bObsweep Pro Robot Vacuum Cleaner Error Codes, "a" and "b" at the lowest order digit of the R compartment. Diagnostics: Use a multimeter when testing it. Error Code Meaning. There is a bad smell in the refrigerator. It is very similar to a washing machine part. Please share your ZIP Code to find a nearby Best Buy to try out your next phone. But opting out of some of these cookies may affect your browsing experience. In the case of the F-FAN HIGH operation, the corresponding LED is turned on. Call a service technician to diagnose and repair this failure. Use a multimeter. "f" at the lowest order digit of the R compartment. ApplianceRepairInfo.com does not guarantee the information to be correct or give a proper diagnosis of any appliance. Then plug it again to restore power and launch the diagnostic mode. Diagnostic: To check it, press on the spring opposite the contact set, with a screwdriver. Often the issue can be resolved with a simple repair or minor part replacement. A Samsung representative at Best Buy will call to schedule your Galaxy S10 try out. I kindly ask at this time that you go ahead and click on the 5th star of the star rating system at the top of your page. (Check if any parts have short-circuited). Check the soldering status of the inverter PCB. The voltage of the MAIN PCB CN74 1↔3: should be between 7V~12V. "d" at the lowest order digit of the F compartment. I followed the reset directions and lights went off, but it’s still not cold. After separating MAIN PCB CN70_1 wire from PCB, resistance value between CN70_1-7 ↔ 3 shall be 63(230) ohm ± 7%. In the case of the CV-FAN HIGHEST operation, the corresponding LED is turned on. In the case of the CV-FAN HIGH operation, the corresponding LED is turned on. Some appliances display the error code when the fault is detected. Communication error between the control panel and electronic control board. The information contained in this website is provided for informational purposes only. Diagnostic: See the Evaporator Thermostat section. • Condensation or water drops may form if the humidity is too high while the. For ice cube generators featuring air-cooled condensers. My fridge had a 34 on it and it wasn’t cold. Any refrigerator unit, including an ice cube generator, features an expansion device. Unplug the refrigerator and check the ice maker wire harness connection. Unplug the refrigerator and check the wire harness connection on the freezer temperature sensor. In the case of the C-FAN LOW operation, the corresponding LED is turned on. Unplug the refrigerator and check the wire harness connections between the inverter board and compressor. "b" and "c" at the lowest order digit of the F compartment. Lime buildup often blocks the nozzles. When necessary, rinse it with a special kind or cleanser. Always take proper safety precautions when installing or repairing any major appliance. If the CV valve opens, the LED is turned on. A thermostat is installed in the container to control and prevent ice buildup. • Some heat is normal as anti-condensators are installed in the vertical hinged section. The temperature sensor is defective. In the case of the C-FAN HIGHEST operation, the corresponding LED is turned on. Check if the sensor is open or shorted The voltage between the Main PCB CN30 pins 7 and 8 should be within the 4.1V~0.8V range. This part is extremely delicate and complex. Possible causes for a Samsung Refrigerator 14E error code. Please, always clean the blades and check the balance when carrying out any maintenance work on the ice cube generator. Create pressure in the water system and directs it toward the spray header. The LED is turned on when the freezer defrosting heater operates. At a set temperature, it disconnects the ice cube generator from mains. When it is over, exit it. "g" at the lowest order digit of the R compartment, "a" at the lowest order digit of the F compartment. The ice maker temperature sensor is open or shorted. In the case of the R-FAN LOW operation, the corresponding LED is turned on. Error Code Cause How to fix; Flashing OF OF: Cooling Off Mode. 1-Confirm the latest software update has been downloaded and installed. The voltage of MAIN PCB CN52-1↔ 6: shall be between 7V~12V. Mostly, it stops the cube ice generator when the condenser becomes dirty. 1-Unplug the refrigerator or turn off power at the circuit breaker. Check if the sensor is open or shorted The voltage between the Main PCB CN30 pins 1 and 2 should be within the 4.5V~1.0V range. Using the ice cube generator for cooling drinks and food. Fisher & Paykel refrigerator troubleshooting, Rangemaster Fridge Freezer troubleshooting. Check if the Sensor is Open or Shorted The voltage between the Main PCB CN30 pins 1 and 3 should be within the 4.5V~1.0V range. In the case of the C-FAN HIGH operation, the corresponding LED is turned on. After separating MAIN PCB CN51 wire from PCB, resistance value between CN51 1↔2 wire shall be 135 ohm± 7%. (Resistance value is varied by input power) 0 ohm : heater short, ∞ ohm : wire/ bimetal open (Must power off), After separating MAIN PCB CN70 wire from PCB, resistance value between CN70_1-7 ↔ 1 shall be 63(230) ohm ± 7%. Water flow stabilizers are marked in colors according to throughput capability. Click on the link below for information that may help you display stored error codes. 4 door Samsung fridge not cooling error 14E. Remove and then put it back in. (This error occurs when the input voltage is AC 106 V or lower.). (Resistance value is varied by input power) 0 ohm : heater short, ∞ ohm : (Must power off). • Check if the set temperature on the digital display is too low. Check if the sensor is open or shorted The voltage between the Main PCB CN30 pins 1 and 4 should be within the 4.5V~1.0V range. When the external temperature is within the range of 22℃~ 33℃. Below, you can see Samsung refrigerator display codes for different common Samsung refrigerator models. Refrigerator compartment temperature sensor failure. The bubbling comes from refrigerant circulating through the refrigerator. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. This is one of the main units, as it regulates the freeze cycle and defrost process. A Samsung Refrigerator displays a 14E error code when a Ice Maker Sensor Error (ice maker inside the refrigerator) has been detected by the internal electronic diagnostics. Diagnostic: Turn the programmer’s stem to ‘defrost’ position using a screwdriver. I unplugged it and after waiting 5 minutes plugged it back in and 1e appeared. This error code appears when there are ice maker issues and it is not related to the freezer fan. If the reason for the error is removed, the error code disappears after a pre-determined period of time. While running the diagnostic mode, please, make sure all temperature indicators are correct. If you have moved the device during a clean-up or home improvement, please, check the hose. Manufacturers: ACC, Aspera, Tecumseh Europe L’Unite Hermetique. The hose’s length (no bends, curves or winding) should match the distance between the ice cube generator and sewer pipe. Check if the door has been open for a long time or if hot food has been stored in the compartment. If you see 14E on the display, it is advisable to reset the fridge. "f" at the lowest order digit of the F compartment. In this case, it is the capillary tube. In the case of the F-FAN HIGHEST operation, the corresponding LED is turned on. • Is the water line connected and the shut-off valve opened? In order to regain normal functionality of the washing machine the problem causing the error code will need to be resolved. Fresh food section on top warm costumer said it was cooling when they unplugged and re-plugged but now error code is back and not cooling. The temperature has been abnormally increased. In the case of the R-FAN HIGHEST operation, the corresponding LED is turned on. • Is there an imbalance between the right and left parts of the door? Unplug the refrigerator and check wire harness connections between the electronic control board and inverter control board. Also, check pressure indication using a low- and high pressure manometer. Check if the sensor is open or shorted The voltage between the Main PCB CN30 pins 11 and 13 should be within the 4.1V~0.8V range. 3-Restore power to the fridge. Check freezer temperature because the ice maker won’t cycle if freezer temperature is above 15 degrees. These unique codes are useful in helping to diagnosis the issue stopping the appliance from functioning properly. In the case of the F-FAN LOW operation, the corresponding LED is turned on. "c" at the second lowest order digit of the F compartment. Installed before the capillary tube, it prevents clogs and dries the cooling loop. Voltage supply to the compressor is too low. These cookies do not store any personal information. A universal micro-motor, for example – Elco 10/20, 230В, 0,20A; output capacity – 5Wt, 1300 rpm. Additional information is available if needed on the Appliance Repair Technical Support page of this website. "a" at the lowest order digit of the R compartment. 8. Reconnect any loose wires. "e" and "f" in the lowest order digits of the R compartment, and the LEDs are all turned off. Check the compressor wire connections. Refrigerator evaporator defrost temperature sensor failure. Unplug the refrigerator and remove the electronic control board cover. Diagnostics: When the unit is up and running, all contacts are closed properly. Unplug the refrigerator and check the ice room temperature sensor wire harness connection.